Quality items from Bonanza’s top-rated sellers.

House Hold Supplies Megastore's booth earned a 99.3% satisfaction rating for providing an excellent experience from start to finish. View booth >>

Rendered at 12:31:21 05/12/25
Full-size item image
Primary image for Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking Drive Through
Free Shipping

Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking Drive Through

£72.06 GBP
Ships from United States Us

Shipping options

Seller handling time is 2 business days Details
No shipping price specified to GB
Ships from United States Us

Return policy

Full refund available within 30 days Details

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Shipping options

Seller handling time is 2 business days Details
No shipping price specified to GB
Ships from United States Us

Return policy

Full refund available within 30 days Details

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Item traits

Category:

Opener Parts & Accessories

Quantity Available:

6 in stock

Condition:

New

UPC:

3561304192268

Model:

DSP-40S

MPN:

DSP-7LP, DSP-6LP

Brand:

Diablo Controls

Type:

Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking

Listing details

Seller policies:

View seller policies

Shipping discount:

Seller pays shipping for this item.

Posted for sale:

More than a week ago

Item number:

1464365287

Item description

Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking Drive Through The DSP-40S detector will add a new dimension of simplicity to your plug-in detector requirements. The DSP-40S has 4 levels of sensitivity which may be changed. At last a plug-in detector that will operate on any voltage from 10 to 30 volts AC or DC. It has been specifically designed to handle parking, drive-through and access control applications where solid-state outputs are required for both the detect and fail outputs. The detector loop inductance should be between 20 and 2000 microhenries. The DSP-40S detector is covered by United States patent number US 7,132,959 ?Non-Interfering Vehicle Detection?. Features Small profile, perfect for many installations Designed to be cross-talk free between other loops Works on any in-ground inductive loop from 20 to 2000 microhenries. Automatically compensates for loop and lead-in sizes Fail-safe operation Wide low-voltage operation Separate Power/Fail and Detect LEDs. LED Indicators: The green Power LED will be on steady to indicate the detector is operating and powered. The red Detect LED will turn on when a vehicle is over the loop detection area. Detect Memory: Power interruptions of short duration are ignored. If power fails for approximately 1 oe seconds or less the detector ?remembers? a vehicle. Sensitivity and Reset Push Button: The Reset/Sens. button is used for two functions. A short press and release of the button will reset the detector and the LED?s will both flash from 1 to 4 times, indicating the detector?s sensitivity level. The detector is shipped from the factory with the sensitivity set at level 3. If a different sensitivity level is required push and continue to hold the button until the LED?s start flashing. Release the button immediately after the desired number of flashes. For example, if the sensitivity is to be changed to level 2, push and hold the button until the LED?s flash twice then immediately release the button. The sensitivity level can always be verified by a quick tap on the push button. This will reset the detector and flash the two LED?s indicating the present level. Level 1 ? Very Low Level 2 ? Low Level 3 ? Normal (Factory setting) Level 4 ? High Loop or Wire Failures: In the case of a loop circuit failure, the green LED flashes slowly (twice per second) for an open loop circuit failure. The green LED will flash fast (10 times per second) to indicate a shorted loop circuit. Fail Safe vs Fail Secure: A fail safe detector will output ?detect? when the loop circuit is failed. This is always useful on a safety loop. On the free exit loop this will keep the gate open until the situation is fixed. This is useful in applications where it is important to allow traffic flow to continue. A fail secure detector will never output ?detect? when the loop circuit is failed. This will keep the gate closed. This is useful in high-security areas or installations where containment is needed. The DSP-40S is a fail safe detector. Note: Never use a fail secure detector on a safety loop. Outputs: Solid-state (open transistor collectors) for both detect and fail outputs. 30 mA maximum current sink- transient voltage protected. Power: 12 to 30 volts DC Operating Temperature: -35F to 165F (-37C to 74C) Size: Height: 2.4? Width: 0.8? Depth: 2.25? Connector: 10-position Molex Type 09-48-1104 Mates with many female PCB 0.156? pitch headers in use by some access control devices and gate operators. 1: Loop input 2: Loop input 3: Power* (10 to 30 volts AC or DC) 4: No Connection 5: No Connection 6: Fail output -connects to common for fail. 7: Fail output -connects to common for fail. 8: Detect output -connects to common for detect. 9: Power* (10 to 30 volts AC or DC) 10: Power Common *Either or both of these pins can be used to supply power to the detector.