Diablo DSP-40S Low Voltage Plug-In Vehicle and 50 similar items
Free Shipping
Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking Drive Through
£72.06 GBP
View full item details »
Shipping options
Seller handling time is 2 business days Details
No shipping price specified to GB
Ships from
United States

Return policy
Full refund available within 30 days
Details
Purchase protection
Payment options
PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted
View full item details »
Shipping options
Seller handling time is 2 business days Details
No shipping price specified to GB
Ships from
United States

Return policy
Full refund available within 30 days
Details
Purchase protection
Payment options
PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted
Item traits
Category: | |
---|---|
Quantity Available: |
6 in stock |
Condition: |
New |
UPC: |
3561304192268 |
Model: |
DSP-40S |
MPN: |
DSP-7LP, DSP-6LP |
Brand: |
Diablo Controls |
Type: |
Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking |
Listing details
Seller policies: | |
---|---|
Shipping discount: |
Seller pays shipping for this item. |
Posted for sale: |
More than a week ago |
Item number: |
1464365287 |
Item description
Diablo DSP-40S Low Voltage Plug-In Vehicle Loop Detector Parking Drive Through
The DSP-40S detector will add a new dimension of simplicity to your plug-in detector requirements. The DSP-40S has 4 levels of sensitivity which may be changed. At last a plug-in detector that will operate on any voltage from 10 to 30 volts AC or DC.
It has been specifically designed to handle parking, drive-through and access control applications where solid-state outputs are required for both the detect and fail outputs. The detector loop inductance should be between 20 and 2000 microhenries.
The DSP-40S detector is covered by United States patent number US 7,132,959 ?Non-Interfering Vehicle Detection?.
Features
Small profile, perfect for many installations
Designed to be cross-talk free between other loops
Works on any in-ground inductive loop from 20 to 2000 microhenries.
Automatically compensates for loop and lead-in sizes
Fail-safe operation
Wide low-voltage operation
Separate Power/Fail and Detect LEDs.
LED Indicators: The green Power LED will be on steady to indicate the detector is operating and powered. The red Detect LED will turn on when a vehicle is over the loop detection area.
Detect Memory: Power interruptions of short duration are ignored. If power fails for approximately 1 oe seconds or less the detector ?remembers? a vehicle.
Sensitivity and Reset Push Button: The Reset/Sens. button is used for two functions. A short press and release of the button will reset the detector and the LED?s will both flash from 1 to 4 times, indicating the detector?s sensitivity level. The detector is shipped from the factory with the sensitivity set at level 3. If a different sensitivity level is required push and continue to hold the button until the LED?s start flashing. Release the button immediately after the desired number of flashes. For example, if the sensitivity is to be changed to level 2, push and hold the button until the LED?s flash twice then immediately release the button. The sensitivity level can always be verified by a quick tap on the push button. This will reset the detector and flash the two LED?s indicating the present level.
Level 1 ? Very Low
Level 2 ? Low
Level 3 ? Normal (Factory setting)
Level 4 ? High
Loop or Wire Failures: In the case of a loop circuit failure, the green LED flashes slowly (twice per second) for an open loop circuit failure. The green LED will flash fast (10 times per second) to indicate a shorted loop circuit.
Fail Safe vs Fail Secure: A fail safe detector will output ?detect? when the loop circuit is failed. This is always useful on a safety loop. On the free exit loop this will keep the gate open until the situation is fixed. This is useful in applications where it is important to allow traffic flow to continue. A fail secure detector will never output ?detect? when the loop circuit is failed. This will keep the gate closed. This is useful in high-security areas or installations where containment is needed. The DSP-40S is a fail safe detector. Note: Never use a fail secure detector on a safety loop.
Outputs: Solid-state (open transistor collectors) for both detect and fail outputs. 30 mA maximum current sink- transient voltage protected.
Power: 12 to 30 volts DC
Operating Temperature: -35F to 165F (-37C to 74C)
Size: Height: 2.4? Width: 0.8? Depth: 2.25?
Connector:
10-position Molex Type 09-48-1104
Mates with many female PCB 0.156? pitch headers in use by some access control devices and gate operators.
1: Loop input
2: Loop input
3: Power* (10 to 30 volts AC or DC)
4: No Connection
5: No Connection
6: Fail output -connects to common for fail.
7: Fail output -connects to common for fail.
8: Detect output -connects to common for detect.
9: Power* (10 to 30 volts AC or DC)
10: Power Common
*Either or both of these pins can be used to supply power to the detector.
Why are we showing these items?
Booth
House Hold Supplies Megastore's booth |
![]() |

-
Refine your browsing experience
We can show you more items that are exactly like the original item, or we can show you items that are similar in spirit. By default we show you a mix.
This item has been added to your cart

View Cart or continue shopping.



Get an item reminder
We'll email you a link to your item now and follow up with a single reminder (if you'd like one). That's it! No spam, no hassle.
Already have an account?
Log in and add this item to your wish list.