Mitsubishi FX2NC-16EYT PLC Expansion Module

One Year Warranty

Output extension block FX 2 NC - 16 EYT

 

Application sequencer FX1NC, FX3GC, FX2NC, FX3UC

 

mass 0.15 Kg

 

Power supply specification

 

Rated voltage Internal power supply from the sequencer

 

power consumption 0.35 W

 

Output specification

 

Number of output points 16 points

 

Output connection shape connector

 

Output type / format Transistor / sink output

 

External power supply DC 5V to 30V

 

Maximum load Resistive load Total load current per 0.1 A / point common (8 points) should be 0.8 A or less.

 

Inductive load 2.4 W / 1 point (24 VDC)

 

Open-circuit leakage current 0.1 mA or less / DC 30 V

 

ON voltage 1.5V or less

 

Response time OFF ? ON 0.2 ms or less / 100 mA

 

ON ? OFF 0.2 ms or less / 100 mA

 

Circuit insulation Photocoupler insulation

 

Output operation indication LED on when driving photo coupler

 

Output circuit configuration

 

Ambient temperature 0 to 55 ° C. ... Operating -20 to 70 ° C. ... Save

 

Relative humidity 35 to 85% RH (noncondensing).... in operation

 

Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2

 

Frequency: 57 to 150 Hz Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (80 minutes in total in total) The criterion is based on IEC 61131-2

 

Impact resistance 147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2

 

Noise immunity Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise si

 

tor with period of 30 to 100 Hz

 

Withstand voltage Between the output terminal (transistor) of the expansion output block and the earth terminal: AC 500 V for 1 minute

 

Insulation resistance Between the output terminal (transistor) and the earth terminal of the expansion output block: 5 MO or more with DC 500 V insulation resistance meter

 

Use atmosphere There is no corrosive property, flammable gas, conductive dust (dust) is not serious

 

Use altitude Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

 

Shipping Weight : 1.2 Kg