We sell only
Quality Equipment We are professional company deals in Healthcare equipment for the last 17 years. Shipped by : Express Post parcel/ DHL courier (6-10 days maximum) Electro Surgical Generator Description Complete range of Electro Surgical Solutions… Model Shalya Easy + Electrosurgical Generator 300W Monopolar + Bipolar, Biocoag Alarm, 10 Prog. 2 Bipolar Modes. Max Power – 70W 4 Cut Modes with optional PULSE CUT Mode for ERCP. Max Power - 300W 3 Coag Modes. Max Power – 120W 6 SENSE Technology ESU PREM Patient Return Electrode Monitoring. Randomized SPRAY Coag Bipolar Cut: in Macro Bip BiCoag Alarm Remote Programmability : from sterile field (optional). Pulse Cut (Optional) for Polypectomy & Papillotomy. User Programmable: TEN Surgical Programs Self Diagnosis Argon Beam Coagulator up-gradable Applications Features of Shalya Easy + 6 SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology. PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns. Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area. Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any. Bipolar Cut : Macro mode can be used for bipolar cutting with hooks and other cutting devices. Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module. User Programmable : TEN Surgical Programs help in setting the system after power ON. BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking. Pulse Cut (Optional) : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy. Soft / Desiccate Coag : Faster cutting with coagulation for thicker tissues & soft coagulation. Remote Power Settings : Change mode and power from sterile field by normal Handswitch Pencil. Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals Time Out Function (Optional) : Automatically stops the HF output if prolong unintended activation. Surgical Applications : Useful for wide range of surgical application as : Plastic, Neuro, ENT, Spine, Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia, GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy, Thoracic and Cardiac Surgery. Unit is suitable for all kind of Open, Endoscopic, Laparoscopic and Minimally Invasive Surgery MONOPOLAR AUTOCUT : Pure Sine wave 390 kHz Sp Cut- Programmable Pulse or continues output, 300 W at 300 ?, CF 1.5 Pure - Continues output, 300 W at 300 ?, CF 1.5 Blend - Bursts repeating at 29 kHz 55% ON cycle, 200 W at 300 ?, CF 2.5 MONOPOLAR COAG : Damped Sine wave 460 kHz Soft - Repetition Frequency 62 kHz, 120 W at 500 ?, CF 5.0 Fulgurate - Repetition Frequency 34 kHz, 120 W at 500 ?, CF 7.0 Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz, 120 W at 500 ?, CF 8.0 BIPOLAR : Pure Sine wave 390 kHz Micro - Lower output voltage, 70 W at 100 ?, CF 1.5 Macro - Higher output voltage, 70 W at 100 ?, CF 1.5 LEAKAGE CURRENTS • RF leakage current • Monopolar : < 150 mA rms • Bipolar : < 60 mA rms • Low Frequency leakage currents • Normal polarity, intact ground : < 10 ?A • Normal polarity, ground open : < 50 ?A PREM SYSTEM Measuring Frequency : 85 kHz ± 10 kHz. Measuring current : < 10 ?A Acceptable Resistance Range upto 40% Dual Area PREM Patient Return Electrode : 5-135 ? (Adaptive) Single Area Patient Return Electrode : < 10 ? FEEDBACK SYSTEM • 3 Microprocessor Controlled 6SENSE Technology with sampling rate above 4000 sense/second • Maximum output power deviation < 15% or 5 watts, whichever is greater at any setting with PER-98 INPUT POWER Operating Voltage : 90-270 Volt AC, (other ratings available on request) Max. Power input : 1000 VA, Fuse : 4 A DIMENSIONS L x W x H in cm - 38.0 x 30.5 x 11.5, Weight in kg < 5.0 DESIGN STANDARD Classification according to the EC- Directive 93/ 42/ EEC: Class IIb General Safety Standards: IEC 60601-1-1, IEC 60601-2-2 EMI/EMC Compatibility Standard: IEC 60601-1-2 IS Safety Standard: IS 7583 Supplied with Standard accessories: 1) Patient Plate return electrode with Cable dual area :1No. 2) Footswitch Single Paddle: 1No. 3) Footswitch Double Paddle:1No. 4) Monopolar Hands switching pencil :1No. 5) Bipolar Forceps, straight, 20cm, 1mm tip:1No. 6) Cord for Bipolar Forcep: 1No. 7) Power cable : 01 No.
8) Operating manual Buyer please note only mentioned accessories will be supplied with the unit. In photograph there is so many other accessories which will not supplied with the unt (Shipping Details) (Contact Detail) (Payment Details ) **Thank you.** |