First, And this is important.

I have been selling for 20 years and have had no Negative or even Neutral reviews. ALWAYS POSITIVE. You don't last 20 years by ripping folks off. Any Item may be returned within 30 days of delivery. If you have an issue send it back for a refund. I’ll even eat the return shipping.

You have NO risk.

These are brand new unused units, purchased in bulk boxes then removed and put in parts bin in tool crib. Project ended, these were left over. These are being sold individually.



General

Number of levels 1
Number of connections 2
Potentials 1
Color blue
Insulating material PA
Flammability rating according to UL 94 V0
Rated surge voltage 8 kV
Degree of pollution 3
Overvoltage category III
Insulating material group I
Maximum load current 150 A (with 50 mm² conductor cross section)
Nominal current IN 150 A
Nominal voltage UN 1000 V
Open side panel No
Ambient temperature (operation) -60 °C ... 85 °C
Ambient temperature (storage/transport) -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C)
Permissible humidity (storage/transport) 30 % ... 70 %
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Static insulating material application in cold -60 °C
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3



Connection data

Connection method Screw connection
Screw thread M6
Stripping length 16 mm
Tightening torque, min 3.2 Nm
Tightening torque max 3.7 Nm
Connection in acc. with standard IEC 60947-7-1
Conductor cross section solid min. 0.75 mm²
Conductor cross section solid max. 50 mm²
Conductor cross section AWG min. 18
Conductor cross section AWG max. 1/0
Conductor cross section flexible min. 0.75 mm²
Conductor cross section flexible max. 35 mm²
Min. AWG conductor cross section, flexible 18
Max. AWG conductor cross section, flexible 2
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 35 mm²
2 conductors with same cross section, solid min. 0.75 mm²
2 conductors with same cross section, solid max. 16 mm²
2 conductors with same cross section, stranded min. 0.75 mm²
2 conductors with same cross section, stranded max. 10 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.75 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 6 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.75 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 10 mm²
Connection in acc. with standard IEC/EN 60079-7
Conductor cross section solid min. 0.75 mm²
Conductor cross section solid max. 50 mm²
Conductor cross section AWG min. 18
Conductor cross section AWG max. 1
Conductor cross section flexible min. 0.75 mm²
Conductor cross section flexible max. 35 mm²
Internal cylindrical gage B9