Model | WZC-60IR | |||||||
Rated voltage | 12/24/48V Auto | |||||||
Rated current |
60A |
|||||||
Maximum protection current |
62A |
|||||||
Battery voltage identification range |
12V(DC9-DC15V); 24V(DC18-DC30V); 48V(DC36-DC60V) |
|||||||
MPPT Operating voltage range | 12V (DC18V~DC150V); 24V(DC34V~DC150V); 48V(DC65V-150V); | |||||||
Maximum PV input power | 900W | |||||||
1700W | ||||||||
3400W | ||||||||
PV input low voltage protection point | 12V:DC16V; 24V:DC30V; 48V:DC60V; | |||||||
PV input low pressure recovery point | 12V:DC18V; 24V:DC34V; 48V:DC65V; | |||||||
Limit input voltage | DC170V | |||||||
PV input overvoltage protection point | DC175V | |||||||
PV input overvoltage recovery point | DC170V | |||||||
charging method | 3 stage :constant currenet(MPPT),equalizing charge,float charge | |||||||
System type | 12/24/48V20-60AAutomatic identify | |||||||
Static power consumption | 2W | |||||||
Machine efficiency | 96.5 %;99 % | |||||||
PV module utilization | 99.97% | |||||||
Float voltage (can be customized) | 12V(13.75V);24V(27.5V)48V(55V); | |||||||
Equalizing charge voltage(can be customized) | 12V(14.2V); 24V(28.4V);48V(56.8V);96V | |||||||
Recommended PV module voltage | 12V(18V-60V); 24V(36V-72V); 48V(72V-144V) | |||||||
Temperature compensation | -3mV℃/2V | |||||||
Temperature protection | 85℃ | |||||||
Temperature rise protection | 80℃ or more to reduce power output | |||||||
Protective function |
PV array short circuit, overvoltage, overcurrent reverse polarity protection,
battery overcharge, reverse protection,Under voltage protection
|
|||||||
Working temperature | -10℃~+45℃ | |||||||
Humidity | 0~90%RH (Not condensation) | |||||||
Altitude | 0~3000m | |||||||
Security Level | CE, PSE, FCC, EMC | |||||||
Mechanical protection class | IP21 | |||||||
Optional battery type | IP21 | |||||||
Product Size |
260*192*80mm/10.2*7.6*3.1in |
|||||||
Weight | Weight: Approx.3475g/121.76 oz |
1*Solar Charge Controller
1* English instruction manual