The Vickers Integrated Motor Pump is a
unique combination of a conventional
AC induction motor cooled with system
hydraulic oil and a Vickers hydraulic
pump, either fixed vane pump or
variable piston type, housed in a special
sound reduction enclosure.
This combination provides an
exceptionally quiet and small pumping
package for any industrial application
requiring up to 125 horsepower (92
kilowatts) of continuous hydraulic power.
The package comes completely
assembled, tested, and ready for
installation.
Circulating the hydraulic oil through the
motor, bathing both the rotor and stator,
makes it possible to obtain twice the
normal continuous output power from
the motor windings. Physical size
reductions of 35% to 50% compared
with conventional pumping packages
are possible as a result. Normal
operation of the motor is not affected by
circulating oil through it, nor is the
system’s hydraulic oil damaged.
Heat generated within the electric motor
is carried away by the hydraulic fluid
and dissipated by the hydraulic cooling
system. A motor fan is not needed,
which makes it practical to cover the
entire assembly (motor and pump) with
a compact, polyethylene sound
reduction enclosure. This reduces the
sound from the pump as well as the
motor, resulting in a noise level
reduction that is unsurpassed in the
industry.
A complete line of standard Vickers
pumps can be fitted to the Integrated
Motor Pump including single fixed vane
pumps, single variable piston pumps,
double vane pumps, double piston
pumps or mixed vane and piston
combinations
Features & Benefits
Smaller package size because of oil
cooled electric motor.
Heat generated by the electric motor is
carried away by the hydraulic fluid.
70% reduction in sound compared to
conventional power unit systems
(approximately 10 dBA).
All external leakage points for both oil
leaking out and air leaking in are
sealed by static o-rings.
External leakage from dynamic shaft
seals has been eliminated.
The specially designed coupling
connecting the pump and motor drive
shafts is oil lubricated and factory
installed by Vickers. This eliminates
labor to align and install the coupling.
Only normal filtration practices are
required.
Meets the requirements of
International Standard IEC 34-5
(1991-01) for IP57 degrees of
protection when installed using a
sealed electrical conduit.
The electric motor stator components
have UL recognition.
Motor bearings are continuously
lubricated by hydraulic fluid.
System sound is significantly reduced
by eliminating the fan and enclosing
the motor and pump.