~~OTC-Over the Counter No RX Script Needed~~
Digital 12 Mode Tens, Safety Amplitude Cap, 100mA output, High Quality Electrodes, Compliance Meter, which makes this Our Nicest and most Powerful (100mA) TENS unit.
TENS 12MT features include:
- Dual Channel
- 12 modes
- Timer
- Patient Compliance Meter
- New Stronger 100mA output
- Safety amplitude cover
- Sturdy metal belt clip
- Rubber side railings for maximum handling
- Premium silver finish.
TENS 12MT Specifications:
Channels: Dual Channel, isolated between channels Pulse Amplitude: Adjustable, 0-100 mA peak into 500 ohm load each channel.
Voltage: 0 - 50V (Load: 500 ohm) Pulse Rate: Adjustable, from 2 to 150 Hz, 1 Hz/step Pulse Width: Adjustable, from 50 to 300 microseconds, 10uS/step
Wave Form: Asymmetrical Bi-Phasic Square Pulse 12 Modes: B(Burst), N(Normal), M(Modulation), SD1(Strength Duration), SD2, P1, P2, P3, P4, P5, P6, P7 Burst Mode: Burst rate: Adjustable, 0-5 ? 5Hz; Pulse width adjustable, 50~300uS; Frequency fixed = 100 Hz Normal Mode: The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value. Modulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300?S) are fully adjustable. The SD1(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%. Total cycle time is 10 seconds. Pulse rate(from 2~150Hz) and pulse width (from 50~300?S) are fully adjustable. The SD2(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range. The intensity is always increasing while the pulse width is decreasing and vice-versa. The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the intensity is increased by 70% while the pulse width is decreased by 70%. Total cycle time is 10 seconds. Pulse rate(from 2~150Hz) and pulse width (from 50~300?S) are fully adjustable. P1 (Burst) Mode Burst rate: 2Hz Pulse width: 180μs Frequency fixed : 100 Hz P2 ( Normal) Mode Pulse rate: 100Hz Pulse width: 180μs P3 (Normal) Mode Pulse rate: 2Hz Pulse width: 200μs P4 (Modulation) Mode Pulse rate: 15Hz Pulse width: 180μs P5 (Modulation)Mode Pulse rate: 80Hz Pulse width: 180μs P6 (SD2)Mode Pulse rate: 10Hz Pulse width: 200μs P7 (SD1) Mode Pulse rate: 50Hz Pulse width: 250μ
Patient Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours.
Timer: Adjustable, from 5 to 60 minutes or Continuous. Adjustable in 5 minutes each step. Treatment time countdown automatically
System Includes: Stimulator, Lead Wires, 1 package of high quality Self-Adhesive Electrodes, 9V Battery, Hard Plastic Carrying Case, Instruction Booklet.