Egg Incubator 36 eggs 110V |
Detailed description: |
1.Working voltage: DC 12V ;AC 110V (actually 110v ,control panel annotation error) 2.Power of heating coil: 35W 3. Relative humidity: less than 85% 4. Ambient temperature: ﹣20℃~70℃ 5. Temperature display range: 0~99.9℃(±0.1℃) 6.Humidity display range: 0~99%RH(±3%RH) |
Display screen, key and parameter setting 1. Display screen: The left is ambient temperature display and the right is humidity display 2. Indicator: The upper parts of the display screen from left to right are respectively customization, chicken, duck, goose, pigeon, heating, humidification, egg turning and alarm. 3.Key: Keys from the left to right are temperature key, humidity key, mode key, egg key, + key and – key. |
Introduction to function |
1、Temperature control function(TH1 is the internal temperature in the incubator.) a.High temperature alarm: The alarm function will start and the buzzer will give a sound when TH1>P1. The alarm function will automatically shut down when TH1<P1. b.Low temperature alarm: The alarm function will start and the buzzer will give a sound when TH1<P4. The alarm function will automatically shut down when TH1>P4. c.Heating function: The heating lamp will be ON and the heating function will start when TH1<P3. The heating lamp will extinguish and the heating function will shut down when TH1>P2. User can set the heating according to the pulse width F5 fuzzy control. 2、Humidity control function(RH1 is the internal humidity in the incubator.) a.High humidity alarm: The alarm function will start and the buzzer will give a sound when RH1>H1. The alarm function will automatically shut down when RH1<H1. b.Low humidity alarm: The alarm function will start and the buzzer will give a sound when RH1<H4. The alarm function will automatically shut down when RH1>H4. 3、Egg turning function a.Manual egg turning: User can press +key to start manual egg turning function in normal working status. It automatically stops after running egg turning time . User can press the + key to stop it immediately. b.Automatic egg turning: The system will automatically turn the egg according to the set egg turning cycle and egg turning time 4、Calibration function User can calibrate it by using accurate thermometer and humidometer due to any derivations of the temperature and humidity sensor for the long term use. User can press +/- key to adjust it when the parameter F3 displays. User can press +/- key to adjust it when the parameter F4 displays. |
Item include:(028322) |
1*Egg Incubator 36 eggs |