This Listing is for (1) ONE Dell OEMR XL R520 Xeon E5-2407 2.2Ghz 6 GB DDR3 Perc H710 Mini
 
The first three photos are a representation of the server you will get
They are all in very similar condition from handling
There are are no dents or abrasions cracks or rust
The rest of the photos are from the IDRAC overview of each one
 
sudo inxi system display follows at the end with a description of methods used
 
This is Pulled and Tested Working
I used
Linux Mint 19.3
Folding AT Home To test the CPU
Memtest for 4 hours
 
Whats in each unit
Dell Service Tag # G3P6J02
318-2065 : 3.5" Chassis with up to 4 or 8  Hard Drives
      9JFWW  ASSY,CHAS,SYSM,8HPHD,V3,R520
319-0019 : Intel Xeon E5-2407 2.20GHz, 10 M Cache, 6.4GT/s QPI, No Turbo , 4C, 80W, Max Mem 1066MHz,OEM ,XL
     8P6G0  PRC,E52407,2.2,10M,SNB,80W,M1 qty1
317-9826 : Heat Sink,PowerEdge
      XHMDT  ASSY,HTSNK,5X2.9X1,R520/420320 qty1
331-4611 : No Additional Processor
370-AAUI : 6GB RDIMM, 1600MT/s, Low Volt,  Single Rank, x8 Data Width
     MVPT4   DIMM,2G,1333,1RX8,8,240,REG,LV qty3
313-9090 : DVD+/-RW, SATA, INTERNAL
      3N3MN  ASSY,DVD+/-RW,SATA,12.7,HLDS,E qty1
342-3529 : PERC H710 Integrated RAID Cont roller, 512MB NV Cache
     5CT6D  ASSY,CRD,CTL,H710,512,NV,MCRD
331-7117 : Risers with up to 4, 3x8 PCIe Slots + 1x16 PCIe Slots
     52P2C  FILLER,BLNK,DIMM,PLSTC,12G  qty5
     8P5T1  ASSY,PWA,RISER-1,1P,R520  qty1
     C67JY  ASSY,PWA,RISER-2,1P,R520  qty1
421-6084 : iDRAC7 Express
331-4604 : Single, Hot-plug Power Supply (1+0), 495W
      FT55X  FILLER,PWRSPLY,12G qty1
      N24MJ  PWR SPLY,495W,RDNT,FLX,V2 qty1
318-2153 : Brand/Bezel, OEM PowerEdge R520 XL
 
Linux Mint sudo inxi -F -m -s
-F, --full           Full output. Includes all Upper Case line letters except -W, plus -s and -n. Does not show extra verbose  options such as -d -f -i -l -m -o -p -r -t -u -x, unless specified.
 
-m, --memory         Memory (RAM) data. Requires root. Numbers of devices (slots) supported and individual memory devices (sticks of memory etc). For devices, shows device locator, size, speed, type (e.g. DDR3). If neither -I  nor -tm are selected, also shows RAM used/total.
 
-s, --sensors        Sensors output (if sensors installed/configured): mobo/CPU/GPU temp; detected fan speeds. GPU temp only for Fglrx/Nvidia drivers. Nvidia shows screen number for > 1 screen. IPMI sensors if present.
 
 
Dell Service Tag # BK28CZ1
System:
  Host: testing Kernel: 5.15.0-58-generic x86_64 bits: 64
    Desktop: Cinnamon 5.6.7 Distro: Linux Mint 21.1 Vera
Machine:
  Type: Server Mobo: N/A model: 051XDX v: A09 serial: ..CN1374039B01CA.
    UEFI: N/A v: 2.9.0 date: 01/09/2020
Memory:
  RAM: total: 5.72 GiB used: 1.67 GiB (29.2%)
  Array-1: capacity: 384 GiB note: check slots: 12 EC: Multi-bit ECC
  Device-1: DIMM_A1 size: 2 GiB speed: spec: 1333 MT/s actual: 1066 MT/s
  Device-2: DIMM_A2 size: 2 GiB speed: spec: 1333 MT/s actual: 1066 MT/s
  Device-3: DIMM_A3 size: 2 GiB speed: spec: 1333 MT/s actual: 1066 MT/s
  Device-4: DIMM_A4 size: No Module Installed
  Device-5: DIMM_A5 size: No Module Installed
  Device-6: DIMM_A6 size: No Module Installed
  Device-7: DIMM_B1 size: No Module Installed
  Device-8: DIMM_B2 size: No Module Installed
  Device-9: DIMM_B3 size: No Module Installed
  Device-10: DIMM_B4 size: No Module Installed
  Device-11: DIMM_B5 size: No Module Installed
  Device-12: DIMM_B6 size: No Module Installed
CPU:
  Info: quad core model: Intel Xeon E5-2407 0 bits: 64 type: MCP cache:
    L2: 1024 KiB
  Speed (MHz): avg: 1200 min/max: 1200/2200 cores: 1: 1200 2: 1200 3: 1200
    4: 1200
Graphics:
  Device-1: Matrox Systems G200eR2 driver: mgag200 v: kernel
  Display: server: X.Org v: 1.21.1.3 driver: X: loaded: modesetting
    unloaded: fbdev,vesa gpu: mgag200 resolution: 1024x768~60Hz
  OpenGL: renderer: llvmpipe (LLVM 13.0.1 256 bits) v: 4.5 Mesa 22.0.5
 Audio:
  Message: No device data found.
  Sound Server-1: PulseAudio v: 15.99.1 running: yes
  Sound Server-2: PipeWire v: 0.3.48 running: yes
Network:
  Device-1: Broadcom NetXtreme BCM5720 Gigabit Ethernet PCIe driver: tg3
  IF: eno1 state: up speed: 100 Mbps duplex: full mac: f0:1f:af:dd:72:5a
  Device-2: Broadcom NetXtreme BCM5720 Gigabit Ethernet PCIe driver: tg3
  IF: eno2 state: down mac: f0:1f:af:dd:72:5b
  Device-3: Dell iDRAC Virtual NIC type: USB driver: cdc_ether
  IF: idrac state: unknown speed: -1 duplex: half mac: f0:1f:af:dd:72:5d
RAID:
  Hardware-1: Broadcom / LSI MegaRAID SAS 2208 [Thunderbolt]
    driver: megaraid_sas
  Hardware-2: Broadcom / LSI MegaRAID SAS 2208 [Thunderbolt]
    driver: megaraid_sas
Drives:
  Local Storage: total: 1.45 TiB used: 31.14 GiB (2.1%)
  ID-1: /dev/sda vendor: Dell PowerEdge RAID Card model: PERC H710
    size: 931 GiB
  ID-2: /dev/sdb vendor: Dell PowerEdge RAID Card model: PERC H710
    size: 558.38 GiB
Partition:
  ID-1: / size: 545.44 GiB used: 15.37 GiB (2.8%) fs: ext4 dev: /dev/dm-1
  ID-2: /boot size: 1.61 GiB used: 402 MiB (24.4%) fs: ext4 dev: /dev/sdb3
  ID-3: /boot/efi size: 512 MiB used: 5.3 MiB (1.0%) fs: vfat
    dev: /dev/sdb2
Swap:
  ID-1: swap-1 type: partition size: 980 MiB used: 0 KiB (0.0%)
    dev: /dev/dm-2
Sensors:
  System Temperatures: cpu: 36.0 C mobo: N/A
  Fan Speeds (RPM): N/A
Info:
  Processes: 258 Uptime: 4h 14m Shell: Sudo inxi: 3.3.13